V. Operation
10
Battery leads connection
Before using the hoist, make sure all electrical components have no corrosion or damaged;
the environment should be clean and dry. The voltage drop from the battery connections to
the hoist must not exceed 10% of the nominal voltage under normal operating condition.
Switch Connection
1. A remote switch with 1.25 mm (diameter) X 3C X 5 m
(16AWG X 3C X 17ft) cord supplied.
2. Open the dust-proof cover of the hoist and then insert
the switch plug into the socket.
Cable-in / Cable-out Operation
1. To determine “Cable - Out”, trigger → out
2. To determine “Cable - In”, trigger ← in
3. To stop hoist, release the trigger
Battery Recommendations
A fully charged battery and good connections are essential for the proper operation of
your hoist. The minimum requirement for battery is 650 cold cranking amp.
Lubrication
All moving parts in the hoist are permanently lubricated at the time of assembly. Under
normal conditions factory lubrication will suffice. If re-lubrication is necessary after repair or
disassembly use marine type grease.